Tecza piping systems has collaborated with a renowned company who manufacture triple-lip sealing rubber seals known as Forsheda 582 Dinlock. These seals along with Ultra fit SWR premium quality UPVC material ensure a long lasting performance. Ultra fit SWR with world class seals are used in building drainage of residential, commercial, industrial, & public complexes.
Single Socket (6 ft.) |
Double Socket (6 ft.) |
Single Socket (3 Mtr.) |
Double Socket (3 Mtr.) |
Double Socket (4 ft.) |
Double Socket (3 ft.) |
Double Socket (2 ft.) |
---|---|---|---|---|---|---|
Size in mm | Size in mm | Size in mm | Size in mm | Size in mm | Size in mm | Size in mm |
75mm | 75mm | 75mm | 75mm | 75mm | 75mm | 75mm |
110mm | 110mm | 110mm | 110mm | 110mm | 110mm | 110mm |
Single Socket (6 ft.) |
Double Socket (6 ft.) |
Single Socket (3 Mtr.) |
Double Socket (3 Mtr.) |
Double Socket (4 ft.) |
Double Socket (3 ft.) |
Double Socket (2 ft.) |
---|---|---|---|---|---|---|
Size in mm | Size in mm | Size in mm | Size in mm | Size in mm | Size in mm | Size in mm |
75mm | 75mm | 75mm | 75mm | 75mm | 75mm | 75mm |
110mm | 110mm | 110mm | 110mm | 110mm | 110mm | 110mm |
Fittings | Pipes | |
---|---|---|
Material | Unplasticized Polyvinyl Chloride (UPVC) |
Unplasticized Polyvinyl Chloride (UPVC) |
Colour | Light Grey | Light Grey |
Reference Standards | IS 14735 : 1999 | IS 13592 : 2013 |
Working pressure (kg/cm2) |
Non Pressure Application | Non Pressure Application |
End Connections | Rubber Ring & Solvent Joint | Rubber Ring & Solvent Joint |
Variants | - | Type 'A' & Type 'B' |
It is imperative to mark the pipe from all sides so that pipe is cut with the help of a Hand Saw. It should be a right angle cut from all the sides. The cut piece should not be with burr on edges.
Remove all the burrs and ridges accumulated on the inner as well as the outer edges of the pipe with the help of a deburring knife, file or abrasive paper.
Thoroughly clean the pipe with dry cloth where the solvent cement is going to be applied, to avoid dust, dirt, oil, moisture and other foreign material during the installation process.
After cutting, the pipe needs to be chamfered from the outer sides. It is advisable to provide approximately2 mm wide, 150 chamfer on spigot end.
Before applying solvent cement, insert the pipe end into the socket of the next pipe or fitting to check that interference occurs at about 1/3 to 2/3 of the socket depth.
Mark the pipe length to be inserted for jointing. Apply a liberal coat of solvent cement with the help of the brushon the marked surface.
Push the pipe inside the fitting so that it goes inside it equally from all the sides. Wipe off excess solvent cement that comes out from all the edges. Hold the joint for to 2 minutes so that the jointing is perfect.
Pipe line should be installed in proper alignment and along with necessary clamps.
Pressure testing to be done before concealing work.
Pressure testing may be carried out after a curing period of 24 hrs.
Do not cut slant/unevenly.
Do not proceed with the installation of pipe without deburring.
Do not join the pipes without cleaning the pipe ends.
Do not proceed with installation of pipe without chamfering.
Do not apply solvent cement without dryfit test.
Do not apply excess solvent cement on the pipe and do not use solvent cement by hand.
Do not use a hammer or half push the pipe.
Don't over tighten with pipe wrench.
Avoid loose joints and misalignments.
Pressure testing should not be done before 24 hrs of curing.